Skip to main content
  • Add
    • Solutions
    • Services
    • Products
    • Agenda
    • Blog
    • Jobs
    • About us
    • Newsletter
    Search
    • EN (Netherlands)
    Home Elscolab
    Mobile menu expand icon Menu Close
    • Industry
    • Water & Environment
    • Laboratory
    • Colour & Appearance
    • Contact
    • Solutions
    • Services
    • Products
    • Agenda
    • Blog
    • Jobs
    • About us
    • Newsletter
    Search
    • NL (Nederland)
    • EN (Netherlands)
    • NL (België)
    • FR (Belgique)
    • EN (Belgium)
    Predicting Maintenance - Calibration pH sensor

    Calibration has never made a sensor better

    Breadcrumb

    1. Home
    2. Blog
    3. Calibration has never made a sensor better
    pH
    Oxygen
    Automatic cleaning and calibration of inline sensors

    Why and especially when do you have to calibrate an inline sensor?

    Inline process analysers and sensors

    The time that industrial processes were monitored by means of regular sampling and analysis in the lab is far behind us. Since the final decades of the last century, process parameters such as pH, conductivity and oxygen have been measured inline and online. Later on, more complex analysers such as refractive index, turbidity meters, TOC analysers and (spectro) photometers were added. 

    This trend was only able to develop owing to the rapid evolution in electronics, digitization and IT. This allowed sensors not only to be made smaller but also sturdier and stabler. Installation in the heart of the processes was also made possible with measurement results becoming more reliable.

    Sensors iSense

    Today process analysers are equipped with self-monitoring, diagnostic functions and algorithms that predict the maintenance frequency. All information, so not only measured values and error messages, but also the internal quality parameters (status) of the process sensor, are available and are digitally passed on to higher process monitoring units (DCS, SCADA, PLC, etc.). Today, the sensors and analysers are self-monitoring and keep us permanently informed of their status and report in detail if something threatens to go wrong.

    Predicting Maintenance - Calibration pH sensor

    Calibration of sensors

    Why is there so much distrust? In- and online sensors (especially oxygen and pH sensors, but also most others) are still regularly calibrated. In most cases this is absolutely unnecessary (and may often be detrimental to the quality of the measurement). We do this mainly out of habit and/or because of bad experience in the past, mostly due to lack of information and thus knowledge. As mentioned, that information is now available in the sensors and analysers and available digitally at all levels.

    But what exactly is calibration? There are many different definitions for this. It always comes down to adjusting the electronic processing (converter, transmitter, etc.) of the raw measurement signal to the current state and quality of the sensor. I.e. if we calibrate a sensor in poor condition, we adapt the electronics so that we can still work with the poor sensor. Result: accuracy, reliability and maintenance frequency deteriorate. With associated costs.

    Preventive maintenance

    Maintenance and cleaning of sensors

    As always, it is better to address the cause instead of fighting the symptoms. If your analyser’s sensor or detector is in poor condition, the cause of this has to be looked for first. Very often this is contamination or adverse damage due to the process. The solution is then cleaning. By cleaning and (preventatively) maintaining the sensor in the right way, you keep it in top condition and regular calibration is unnecessary.

    Owing to the current digitization of sensors and analysis systems, the current status is being closely followed. Its evolution of this can be viewed remotely via DCS, SCADA or another platform and reports may be generated automatically.

    External influences during calibration

    Obviously, calibration is necessary from time to time. But only if there is the right reason for it. If you perform a calibration anyway, make sure that all preconditions are fulfilled. 

    The key thing is to ensure that the analyser's sensor or detector is clean and in good condition. You then have to check whether the calibration standards used comply with the standards (expiration date, storage, handling). Furthermore, the method of calibration is of great importance. Influences, including from temperature, pressure and air humidity must be taken into account, or better still, be avoided if possible. If standards (e.g. calibration gases) are used, it is very important that couplings and tubing do not leak, do not absorb oxygen (or other gases or vapours) and absorb moisture by diffusion through the pipe wall and not contribute to temperature or pressure changes. Dirty cups, reused standards and incorrect manipulations have often been the cause of poor calibration and therefore incorrect measurement results.

    In- and online analysis technology is a discipline in its own right. Maintenance and calibration should therefore be carried out by analysis specialists with the necessary knowledge. Good and reliable analysis is a necessary prerequisite for accurate and reliable process analysis. And maintenance and calibration require time and expertise. Hence this advice: calibrate as little as possible, only if necessary, and do it the right way.

    More information?

    Contact us
    • Elscolab | Service | Preventive maintenance

      Preventive maintenance

      Every sensor, device or analyser must be maintained in good time to ensure quality and avoid high repair costs.

      Read more

    Newsletter

    Keep up-to-date with innovations, applications and possibilities as well as events, seminars and webinars by subscribing to our newsletter.

    Subscribe
    pH
    Oxygen

    Share

    Facebook
    Twitter
    Print
    E-mail
    Linkedin

    Related blog items

    BASF - Waste Water

    Case study: Stable pH measurement for reliable water treatment

    25 February 2026
    Read more
    Evonik pH measurement

    Case study: Boost process efficiency and safety with an intelligent pH solution

    30 June 2025
    Read more
    Knick - Inline analyzers in pharma and biotech

    Inline process analysers in pharma and biotechnology

    31 May 2024
    Read more
    Bayer Agriculture Refractometer

    Case study: Guaranteed product quality and cost savings through inline refractometry and pH measurement

    2 April 2024
    Read more
    Inline Gas Measurement - MT GPro500 TDL

    Boost your oxygen analyser

    22 January 2024
    Read more
    ISM Core | Intelligent platform for inline liquid analysis

    ISM: The intelligent platform for inline liquid analysis

    22 August 2023
    Read more
    logo
    Your partner for a reliable continuity of measurements, processes and applications.
    Contact

    Sitemap

    • Industry
    • Water & Environment
    • Laboratory
    • Colour & Appearance
    • Solutions
    • Services
    • Products
    • Agenda
    • Blog
    • Jobs
    • About us
    • Newsletter

    Contact

    ELSCOLAB BV
    Da Vincilaan 11 b
    6716 WC Ede
    Netherlands
    +31 (0)342 42 60 80
    contact@elscolab.com
    © Elscolab 2026
    • General conditions
    • Privacy policy
    • Cookie policy
    • Disclaimer
    • Change cookie preferences
    Powered by Dropsolid