    From biodecontamination to validation: how to keep your biosafety cabinet reliable

    Breadcrumb

    1. Home
    2. Blog
    3. From biodecontamination to validation: how to keep your biosafety cabinet reliable
    Lab Safety

    A biosafety cabinet protects your employees from exposure to infectious material, prevents the contamination of samples and products, and keeps organisms, spores, and aerosols safely contained within the cabinet. Without regular maintenance and checks, you risk a false sense of security. You can learn below which steps are necessary to keep your cabinet reliable and compliant with current standards.

    Faster-Amira_Biodecontaminatie_SafeFast-Premium

    Start every maintenance job safely

    Before commencing any maintenance or filter replacement, thorough decontamination is essential. This is often carried out using V-PHP (vapour-phase hydrogen peroxide), a biocide that disperses homogeneously throughout the cabinet, reaching even hard-to-access areas. This achieves a 6-log reduction of microorganisms on all exposed surfaces, including the HEPA filter surfaces. Once complete, no residue is left behind, as the agent breaks down into water and oxygen. 

    A validated decontamination process not only protects the cabinet users but also ensures that maintenance and servicing can be carried out safely.

    Faster SafeFast Classic

    Preventive maintenance extends the lifespan

    Waiting for something to break is rarely a good strategy. Without preventive maintenance, the unit's performance gradually declines, breakdowns occur more frequently, and repair costs escalate.

    During a service visit, service engineers inspect all critical components and replace parts that are subject to wear and tear as needed. If the filters need replacing, this can be done following decontamination, ensuring the cabinet can be safely returned to service quickly.

    By having biodecontamination, maintenance, and validation carried out by a single specialised partner, the various interventions are optimally coordinated. This minimises biosafety cabinet downtime, simplifies scheduling, and ensures you have a single, dedicated point of contact for all technical queries.

    Validation confirms that everything is working correctly

    Following maintenance or filter replacement, it is crucial to verify that the cabinet still provides the required level of protection. To this end, a thorough validation is conducted in accordance with applicable standards, such as EN 12469-2:2025 for microbiological safety cabinets.

    During this validation, airflows and air velocities, HEPA filter integrity, alarm functions, sensors, and particle concentrations are checked, among other things. If present, UV systems are also inspected.

    The technicians carrying out these checks are fully trained and use certified measuring equipment and reference standards. This ensures that the results are reliable and that your cabinet meets the required standards.

    For most biosafety cabinets, annual validation is recommended. In addition, requalification is required following relocation, maintenance work, or filter replacement.

    • Faster SafeFast Premium
      Faster SafeFast Premium
    • Faster SafeFast Premium
      Faster SafeFast Premium
    • Faster SafeFast Premium
      Faster SafeFast Premium

    Continuous monitoring of protection

    Even between scheduled interventions, a biosafety cabinet continuously monitors its own operation. Depending on the cabinet type, sensors track airflows, filter status, and other critical parameters.

    If protection is compromised, for example due to disrupted airflow or a saturated filter, an alarm is automatically triggered. This allows users to take immediate action, ensuring that both product and personnel protection (in class II cabinets) remain guaranteed.

    Want to ensure the reliable operation of your biosafety and laminar flow cabinets? Contact Elscolab for tailor-made biodecontamination, maintenance and validation services.

    Contact us
    • Service - Biodecontaminatie - Amira

      Biodecontamination and Validation of Biosafety Cabinets

      Ensure a safe and sterile environment with professional biodecontamination, validation and preventive maintenance of your laminar flow and biosafety cabinets.

      Read more
    • LAB-10_Faster-SafeFastPremium_Testimonial_PGI-NonWoven-Berry

      Testimonial: Improved safety for operators and samples with a suitable LAF cabinet

      Increase your safety with the right LAF cabinet. Discover how a good laminar flow can protect your employees, your samples and your environment.

      Read more
    • Lab Safety - Clean Rooms (laminar flow) & Safety Cabinets

      The differences between Class I, II and III Microbiological safety cabinets

      What type of microbiological safety cabinet do you actually need in your laboratory?

      Read more

    Newsletter

    Keep up-to-date with innovations, applications and possibilities as well as events, seminars and webinars by subscribing to our newsletter.

    Subscribe
    Lab Safety

    Share

    Facebook
    Twitter
    Print
    E-mail
    Linkedin

    Related blog items

    Faster cabinets with different flows

    The impact of airflow: horizontal versus vertical flow in the laboratory

    16 September 2025
    Read more
    ATI Gas - Gas & water

    Leading Gas Monitoring Solutions of the Future

    24 June 2024
    Read more
    LAB-10_Faster-SafeFastPremium_Testimonial_PGI-NonWoven-Berry

    Testimonial: Improved safety for operators and samples with a suitable LAF cabinet

    13 June 2024
    Read more
    Safe preparation of medicines

    PIC/S standardisation for hospital pharmacies

    10 May 2023
    Read more
    The difference between HEPA and ULPA filters

    The difference between HEPA and ULPA filters

    10 May 2023
    Read more
    Lab Safety - Clean Rooms (laminar flow) & Safety Cabinets

    The differences between Class I, II and III Microbiological safety cabinets

    1 April 2022
    Read more
    logo
    Your partner for a reliable continuity of measurements, processes and applications.
    Contact

    Sitemap

    • Industry
    • Water & Environment
    • Laboratory
    • Colour & Appearance

    Contact

    ELSCOLAB NV
    Hogenakkerhoekstraat 14
    9150 Kruibeke
    Belgium
    +32 (0)3 250 15 70
    contact@elscolab.com
    © Elscolab 2026
    • Terms and conditions
    • Privacy policy
    • Cookie policy
    • Disclaimer
    • Change cookie preferences
    Powered by Dropsolid