    Biogas Plant

    How do you quantify and solve the negative effects of moisture in a biogas plant?

    Breadcrumb

    1. Home
    2. Blog
    3. How do you quantify and solve the negative effects of moisture in a biogas plant?
    Biogas
    Biogas Plant - Measurement Points

    The influence of moisture during the production of biogas and biomethane is often underestimated. Moisture nevertheless has a significant impact on the efficiency and service life of key components and the cost of maintaining the entire installation. Continuous and permanent measurement of moisture content can prevent many issues and save a considerable amount of money. 

    Raw biogas naturally contains high levels of moisture after fermentation, up to 100% relative humidity (%RH). In addition to moisture (or water), biogas usually contains H2S, siloxanes and volatile organic compounds (VOC) that must be removed before biogas and biomethane can be used as an energy source.

    Biogas - Active carbon filtration

    An activated carbon filter does not handle too high or too low moisture levels very well

    After drying raw biogas from the digester, the gas is passed over an activated carbon filter to remove impurities. The moisture levels of the biogas, the relative humidity, largely determines the efficiency of the activated carbon. Too high moisture levels lead to condensation and can render the filters completely unusable. The biogas must therefore be sufficiently dried beforehand. However, if the moisture level is too low, it is also bad for the activated carbon filter. The optimum relative humidity is between 50 and 70%. Too much drying of the gas before it goes to the activated carbon filter, in turn, is bad for H2S removal.

    Proper monitoring of relative humidity dramatically extends the service life of activated carbon filters, even doubling it. Considering that a refill or regeneration costs about € 3000 on average, this is a substantial saving. A poorly functioning filter means H2S passes through. This is a very corrosive gas and the cost resulting from corrosion of pumps, betters, motors, etc. quickly adds up. All the more reason to consider continuous moisture measurement.

    Heat exchangers

    The easiest and most conventional way to reduce the moisture level of a gas stream is through cooling and then reheating. During cooling, the moisture condenses and dissipates. After warming, the relative humidity is noticeably lower. This principle is based on thermal equilibrium, in other words, that the gas stays in the cooling system long enough. In practice, that is rarely the case. The only way to determine the moisture content with certainty is to measure it at the outlet of the heat exchanger. When it comes to biomethane production, the biogas requires further drying and moisture measurement is even more important. 

    Biogas - CHP - Combined heat and power engine

    CHP

    In CHP (combined heat and power), biogas is converted into energy. This obviously needs to be done with the highest possible efficiency. Did you know that when the moisture level in the biogas is reduced by 1% vol., the heat capacity increases by 1%? 

    Pressure and temperature fluctuations lead to condensation in the motor and consequently corrosion by H2S. CHP manufacturers specify the maximum permissible moisture content. Damage due to corrosion is therefore not covered by the warranty. Proper drying with control is therefore a necessity, not a luxury. Once you understand that moisture in the biogas has an impact on lubricating the motor (the time between oil changes can be halved), you can better control the expenses.

    Biogas - Membrane technology

    Biomethanisation: Avoid moisture!

    Biomethane (CH4) is essentially made by extracting CO2 from biogas. Separation of CH4 and CO2 is done by membranes under elevated pressure (> 10bar). When the dew point (the temperature at which condensation occurs and thus related to moisture content) of the biogas before compression is too high, you get condensation, even at a higher temperature. It is essential to keep the dew point below 0°C to ensure trouble-free methanisation.

    Biogas - Vaisala Multigas Probe

    Measuring moisture in a biogas plant

    Water, or more accurately, water vapour, is measured using the same technology used to measure methane (CH4) and CO2, i.e. infrared absorption. An infrared light beam of a known intensity is passed through the gas. The water molecules present absorb some of the light. The intensity of the light captured by the detector is measured. The ratio of the initial to measured light intensity is used as a measure of concentration. 

    VAISALA's MGP261 biogas analyser, which is distributed in Benelux by ELSCOLAB, is specifically designed for the simultaneous and continuous analysis of CH4, CO2 and moisture in biogas and biomethane production. There is no risk of corrosion and/or condensation due to its construction. The analyser is so stable that verification or calibration is required only once a year. The return on investment in an MGP261 is relatively short due to the costs you save by controlling moisture in the biogas.

    • Biogas production

      Calculate the efficiency of your biogas plant on the basis of the correct data

      Discover how to improve the efficiency of your biogas installation by determining the amount of moisture in biogas.

      Read more
    • Biogas Production - CH4, CO2 & H2O measurement

      From waste to bio energy

      Achieve the best possible efficiency in your energy production by improving your methane production and measuring the moisture levels! Explore the advantages!

      Read more
    • Vaisala Biogas analyser

      Biogas analyser

      View product

    Newsletter

    Keep up-to-date with innovations, applications and possibilities as well as events, seminars and webinars by subscribing to our newsletter.

    Subscribe
    Biogas

    Share

    Facebook
    Twitter
    Print
    E-mail
    Linkedin

    Related blog items

    Vaisala | Biogas analysers help reduce CO2 emissions

    Biogas analysers help to achieve major goals

    18 January 2024
    Read more
    Renewable Energy | Biomethane

    Get the most from biomethane

    25 September 2023
    Read more
    Biogas production

    Calculate the efficiency of your biogas plant on the basis of the correct data

    11 October 2021
    Read more
    logo
    Your partner for a reliable continuity of measurements, processes and applications.
    Contact

    Sitemap

    • Industry
    • Water & Environment
    • Laboratory
    • Colour & Appearance

    Contact

    ELSCOLAB BV
    Da Vincilaan 11 b
    6716 WC Ede
    Netherlands
    +31 (0)342 42 60 80
    contact@elscolab.com
    © Elscolab 2026
    • General conditions
    • Privacy policy
    • Cookie policy
    • Disclaimer
    • Change cookie preferences
    Powered by Dropsolid