    BASF - Waste Water

    Case study: Stable pH measurement for reliable water treatment

    Breadcrumb

    1. Home
    2. Blog
    3. Case study: Stable pH measurement for reliable water treatment
    pH
    Testimonial

    pH measurements in polymer-containing process flows are challenging, especially when it comes to wastewater. At BASF Heerenveen, pH fluctuations caused disruptions in the ultrafiltration installation. In this case study, you can read how an automatic cleaning solution delivers stable pH measurements, reduced maintenance and reliable operation of the water treatment process.
     

    BASF Heerenveen, specialist in water-based polymers for inks and coatings

    BASF in Heerenveen develops and produces water-based binders for the printing ink and coating industry. A large part of these polymers is used in sustainable inks for food packaging. These additives contribute to the optimal colour and gloss quality of paints and coatings.
     

    The automatic cleaning of the pH sensor ensures reliable measurement without any extra effort on the part of our employees.

    Mark Lazonder, Asset Manager BASF Netherlands

    BASF - Waste Water

    Stable pH measurement in a polluting water flow

    pH measurement in water treatment

    Well-controlled water treatment plays an important role in this production environment. In Heerenveen, the polymer-containing process flow is first treated by ultrafiltration (UF) before the permeate water enters the internal water treatment system.

    The UF installation is used to thicken polymers from the influent. The water passes through the membranes, while the thickened polymer fraction is collected and reused. The efficiency of this thickening process is highly dependent on the pH value of the process flow, however. 

    BASF Heerenveen - Knick UniClean 710

    In practice, pH fluctuations were found to have a negative impact on the thickening factor of the UF installation. If the pH was too low or unstable, insufficient polymer was collected. This not only impacted the efficiency of the process, but also the operational reliability of the water treatment.

    Initially, there was little control due to a lack of continuous measurement. Manual measurements showed that the pH was often outside the optimal range, which was not noticed in time.

    An additional challenge is the film-forming behaviour of the polymers present, which easily adhere to surfaces, including pH sensors, causing contamination and compromising reliability.

    BASF Heerenveen - Knick UniClean 710

    Measurement objective: insight and control

    BASF wanted to continuously monitor the pH value upstream of the ultrafiltration installation. Accurate measurement of this value allows the pH to be adjusted in good time by means of dosing, before the process flow reaches the UF installation.

    Stable and continuous pH measurement allows for:

    • optimisation of the thickening factor of the UF installation
    • thickening of polymers

    This is why low-maintenance and reliable pH measurement was necessary, even in this complex and polluting process flow.

    The pH measurement remains stable: re-calibration was not necessary even after six months.

    Mark Lazonder, Asset Manager BASF Netherlands

    Automatic cleaning for reliable pH measurements

    To ensure reliable pH measurements, BASF opted for an inline pH solution with automatic cleaning. The installation consists of:

    • a Knick Stratos Multi transmitter
    • a Knick Uniclean 720 for automatic sensor cleaning
    • a pneumatically controlled retractable fixture

    This setup automatically retracts the pH sensor from the process pipe and cleans it with water. The Uniclean 720 controls both the cleaning and retraction of the sensor, fully integrated into the process.

    This approach greatly reduces sensor contamination and ensures long-term reliable pH measurement without interrupting the process.

    • Knick UniClean 710
      Knick UniClean 710
    • Knick UniClean 710
      Knick UniClean 710
    • Knick Stratos Multi
      Knick Stratos Multi

    Stable measurement without extra effort

    Automatic cleaning guarantees stable and reproducible pH measurement, even in a flow containing polymers. Sensor maintenance has been significantly reduced and manual intervention by the maintenance team is now hardly ever necessary.

    This contributes to:

    • better controlled operation of the ultrafiltration unit
    • more stable water treatment process
    • less work pressure for employees
    BASF Heerenveen - Knick UniClean 710

    Collaboration with ELSCOLAB

    BASF was able to count on ELSCOLAB's technical support for this atypical pH application. Through joint deliberation about the application and the correct configuration, a solution was developed that meets the specific process requirements.

    BASF experienced the collaboration as pleasant, open and transparent, with clear technical support throughout the process.

    Are you also looking for reliable pH measurement in a complex process flow?

    Elscolab supports customers with simple to challenging measurement applications in process and water environments. Contact us for tailored technical advice and discover how you can make your process measurements reliable and low maintenance.
     

    Contact us
    • Automatic cleaning and calibration of inline sensors

      Automatic cleaning and calibration of inline sensors

      A dirty or corroded sensor does not measure correctly. They need frequent maintenance. What if you could easily automate this task?

      Read more
    • Knick Retractable probe

      Retractable probes

      View product
    • Knick cCare Automatic Cleaning & Calibration

      Automatic cleaning/calibration

      View product

    Newsletter

    Keep up-to-date with innovations, applications and possibilities as well as events, seminars and webinars by subscribing to our newsletter.

    Subscribe
    pH
    Testimonial

    Share

    Facebook
    Twitter
    Print
    E-mail
    Linkedin

    Related blog items

    Evonik pH measurement

    Case study: Boost process efficiency and safety with an intelligent pH solution

    30 June 2025
    Read more
    LAB-10_Faster-SafeFastPremium_Testimonial_PGI-NonWoven-Berry

    Testimonial: Improved safety for operators and samples with a suitable LAF cabinet

    13 June 2024
    Read more
    Knick - Inline analyzers in pharma and biotech

    Inline process analysers in pharma and biotechnology

    31 May 2024
    Read more
    Testimonial IMD | Vaisala K-Patents | Refractometer for raw materials in waste water

    Testimonial: Extracting raw materials and optimising processes through inline measurement on wastewater

    29 April 2024
    Read more
    Bayer Agriculture Refractometer

    Case study: Guaranteed product quality and cost savings through inline refractometry and pH measurement

    2 April 2024
    Read more
    ISM Core | Intelligent platform for inline liquid analysis

    ISM: The intelligent platform for inline liquid analysis

    22 August 2023
    Read more
    logo
    Your partner for a reliable continuity of measurements, processes and applications.
    Contact

    Sitemap

    • Industry
    • Water & Environment
    • Laboratory
    • Colour & Appearance
    • Solutions
    • Services
    • Products
    • Agenda
    • Blog
    • Jobs
    • About us
    • Newsletter

    Contact

    ELSCOLAB BV
    Da Vincilaan 11 b
    6716 WC Ede
    Netherlands
    +31 (0)342 42 60 80
    contact@elscolab.com
    © Elscolab 2026
    • General conditions
    • Privacy policy
    • Cookie policy
    • Disclaimer
    • Change cookie preferences
    Powered by Dropsolid